Bug #19617

[BCR-1093-24][MIB BE] Clean Up Process for Expired Pending Device Binding

Added by Nor Khairun Aqila Jesmen 9 months ago. Updated 8 months ago.

Status:ClosedStart date:30 January 2024
Priority:NormalDue date:
Assignee:Nor Khairun Aqila Jesmen% Done:

0%

Category:-Estimated time:1.00 hour
Target version:-Spent time:1.00 hour

Description

Issue:
BIBD user unable to unbind Primary device with expired Pending Secondary.

Fixes suggestion:
To have clean up process every 5 minutes for last 24hours record and change any "Pending" status to "Expired" status for expired Device Binding

History

#1 Updated by Nur Azza Syazwany Azizol 9 months ago

  • Status changed from New to Resolved
  • Assignee changed from Nur Azza Syazwany Azizol to Nor Khairun Aqila Jesmen
  • Estimated time set to 1.00

Add new java file
MiB

DeviceBindingPendingCleanUp.java

#2 Updated by Nor Khairun Aqila Jesmen 9 months ago

Tested good

#3 Updated by Feerman Yusoff 8 months ago

  • Status changed from Resolved to Closed

Also available in: Atom PDF